Leprecon LPC V2 User's Manual Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 122
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
LPC 48 / 96 Users Manual
Page 16
Figure 6: Patch List Screen
3.5 Edit the Custom Patch
The Patch can now be edited in two ways; by Dimmer, or by Channel. The
choice can be made by selecting the tabs located on the left column, (See Figure
7). In this example we will create a patch by using the channel method.
1. Select the Edit tab on the left column
2. Select the Add tab on the left column and the control window opens.
3. By Channel (default), select desired Console channel the dialog box.
4. Enter desired light Level (default is 100%).
5. Choose DMX Line output A or B.
6. Enter desired dimmer DMX channel number(s) by selecting the Dim
Window which will highlight in yellow.
7. Use the command keys on console Dim, Thru, Except, And to enter a
patch string. Use the format example: Dim 1 Thru 12 And 22 Enter.
8. Select Save and Exit to go back to the patch list screen.
Zobrazit stránku 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 121 122

Komentáře k této Příručce

Žádné komentáře